1、通过补录地址:http://dc.kportal.*.com:6080/dataCollection/#/
(1)跟踪查看域名解析地址:对应的是地址58.211.*.*:6080——172.18.2.67:6080
(2) 但是这个172.18.2.67:6080是访问不了的。
(3)再次查看172.18.2.67,是haproxy代理,同时也是vip(172.18.2.65,172.18.2.66的虚拟地址)地址,172.18.2.67:6080实际地址为172.18.2.65:6080或172.18.2.66:6080
(4)检查172.18.2.65:6080,172.18.2.66:6080,发现目前2.67指向到172.18.2.66,发现2.66的6080无法访问(2.66是备端),应该是服务没起来;
(5)再检查2.65发现系统无法登录,系统错误,原因为上次停电遗留问题,通过fsck解决;
(6)进入2.65,启动服务,关闭2.66的keepalive服务,让2.67指向2.65,此时2.67:6080服务通了
(7)查看端口使用情况:发现6080,7080,8080,18080,9080等都是通过haproxy代理转发
(8)查看配置文件,都是指向各自服务器;
[root@Bigdata_HAProxy_1_PRD ~]# cat /etc/haproxy.cfg global pidfile /var/run/haproxy.pid chroot /opt/haproxy uid 99 gid 99 daemon nbproc 1 ulimit-n 65536 log 127.0.0.1 local0 info defaults mode tcp option abortonclose #option redispatch retries 2 maxconn 4096 timeout connect 1d timeout client 1d timeout server 1d listen status mode http bind 0.0.0.0:9100 stats enable stats uri /haproxy-stats stats refresh 10s monitor-uri /stats stats auth admin:stats stats show-legends stats admin if TRUE frontend hive-Master-10001 bind *:10001 mode tcp option tcplog maxconn 512 default_backend hive-backend backend hive-backend balance leastconn server Hive_BigDataHadoopNN1PRD 172.18.2.38:10000 check inter 1000 rise 1 fall 10 server Hive_BigDataHadoopNN2PRD 172.18.2.39:10000 check inter 1000 rise 1 fall 10 server Hive_BigDataHadoopCMPRD 172.18.2.50:10000 check inter 1000 rise 1 fall 10 server Hive_BigDataHadoopHS4PRD 172.18.2.73:10000 check inter 1000 rise 1 fall 10 frontend Impala-Master-21051 bind *:21051 mode tcp option tcplog default_backend Impala-backend backend Impala-backend mode tcp balance leastconn server Impala_BigDataHadoopDN1PRD 172.18.2.40:21050 check inter 3000 rise 3 server Impala_BigDataHadoopDN2PRD 172.18.2.41:21050 check inter 3000 rise 3 server Impala_BigDataHadoopDN3PRD 172.18.2.42:21050 check inter 3000 rise 3 server Impala_BigDataHadoopDN4PRD 172.18.2.43:21050 check inter 3000 rise 3 frontend hue-Master-8889 bind *:8889 mode tcp option tcplog maxconn 512 default_backend hue-backend backend hue-backend balance source server hue_BigDataHadoopNN1PRD 172.18.2.38:8888 check inter 1000 rise 1 fall 10 server hue_BigDataHadoopNN2PRD 172.18.2.39:8888 check inter 1000 rise 1 fall 10 frontend namenode-Master-9022 bind 0.0.0.0:9022 mode tcp option tcplog default_backend namenode-backend backend namenode-backend mode tcp balance leastconn #cookie biSRV insert indirect nocache option httpchk GET /jmx?qry=Hadoop:service=NameNode,name=NameNodeStatus http-check expect string active server nn_BigDataHadoopNN1PRD 172.18.2.38:8020 cookie s1 check port 50070 inter 3000 rise 3 server nn_BigDataHadoopNN2PRD 172.18.2.39:8020 cookie s2 check port 50070 inter 3000 rise 3 frontend openldap-389 bind *:389 mode tcp option tcplog default_backend pool_ldap backend pool_ldap balance leastconn mode tcp server ldap_BigData_APP_Clu_1_PRD 172.18.2.44:389 check inter 3000 rise 3 server ldap_BigData_APP_Clu_2_PRD 172.18.2.45:389 check inter 3000 rise 3 frontend portal-7080 bind *:7080 mode http option tcplog default_backend portal-backend backend portal-backend mode http balance source server portal-BigData_APP_Clu_1_PRD 172.18.2.44:7080 check inter 3000 rise 2 server portal-BigData_APP_Clu_2_PRD 172.18.2.45:7080 check inter 3000 rise 2 backup frontend cas-9080 bind *:9080 mode http option tcplog default_backend cas-backend backend cas-backend mode http balance source server cas-BigData_APP_Clu_1_PRD 172.18.2.44:9080 check inter 3000 rise 2 server cas-BigData_APP_Clu_2_PRD 172.18.2.45:9080 check inter 3000 rise 2 backup frontend ceo-9999 bind *:9999 mode http option tcplog default_backend ceo-backend backend ceo-backend mode http balance source server ceo-BigData_APP_Clu_1_PRD 172.18.2.44:9999 check inter 3000 rise 2 server ceo-BigData_APP_Clu_2_PRD 172.18.2.45:9999 check inter 3000 rise 2 frontend YH-BI-8080 bind *:8080 mode http option tcplog default_backend yh-bi-backend backend yh-bi-backend balance source mode http server YH-BI-BigData_YH_Report_1_PRD 172.18.2.51:8080 check inter 3000 rise 2 #server YH-BI-BigData_YH_Report_2_PRD 172.18.2.52:8080 check inter 3000 rise 2 frontend metadata-portal-18080 bind *:18080 mode http option tcplog default_backend metadata-portal-backend backend metadata-portal-backend mode http balance leastconn #server mss-BigData_APP_Clu_3_PRD 172.18.2.46:18080 check inter 3000 rise 2 server metadata-BigData_APP_Clu_4_PRD 172.18.2.47:18080 check inter 3000 rise 2 frontend bl-portal-6080 bind *:6080 mode http option tcplog default_backend bl-backend backend bl-backend mode http balance leastconn server bl-BigData_APP_Clu_3_PRD 172.18.2.46:6080 check inter 3000 rise 2 #server metadata-BigData_APP_Clu_4_PRD 172.18.2.47:18080 check inter 3000 rise 2
(7)登录http://dc.kportal.*.com:6080/dataCollection/#/可以正常访问
2、http://cas.kportal.*.com:9080/
(1)http://kportal.*.com:7080/portal